Amprobe/Wavetek 33XR-A Manual Ranging Digital Multimeter
|
|
Item Number: 33XR-A
Manufacturer: Fluke-Wavetek
|
Amprobe/Wavetek 33XR-A
Manual Ranging Digital Multimeter
Manual ranging digital multimeter with temperature and capacitance for field service technicians.
For
more features and specs on Capacitance,Temperature, Frequency
(autoranging), Diode Test, Continuity, Peak Hold, Overload Protection
please click on the Detailed Specs link.
- Min/Max, Relative, Peak and Data Hold
- Auto power off to save battery life
- Separate door for easy battery and fuse access
- Magne-Grip™ Holster with magnetic hanging strap
- Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph
- Display Update Rate: 2/sec, nominal
- Analog bar graph
- Overrange indication
- Operating Temperature: 0 °C to 45 °C at < 70 % R.H.
- Storage Temperature: -20 °C to 60 °C,
- Input warning tone when test leads are in wrong jack
F E A T U R E S
| Warranty:
|
One-Year
|
| Battery Life:
|
300 hrs typical (alkaline)
|
| Size:
|
7.7" x 3.5" x 2.3" (196 x 92 x 60 mm)
|
| Weight:
|
(without holster, including battery): 0.9 lb (400 gr
|
| Safety:
|
Cat II 1000V, Cat III 600V
|
|
|
| Instruction Manual:
|
Yes
|
| Detailed Specs:
|
Yes
|
| Hi-Resolution Image:
|
Yes
|
S P E C I F I C A T I O N S
| DC Voltage Ranges:
|
|
400 mV, 4 V, 40 V, 400 V, 1000 V
|
| DC Voltage Accuracy:
|
|
all ranges: ± (0.7 % rdg + 1 dgt)
|
| DC Voltage Resolution:
|
|
100 μV
|
| DC Voltage Input Impedance:
|
|
10 MΩ
|
| AC Voltage (45 Hz to 500 Hz) Ranges:
|
|
400 mV, 4 V, 40 V, 400 V, 750 V
|
| AC Voltage (45 Hz to 500 Hz) Accuracy:
|
|
4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts)
|
| AC Voltage (45 Hz to 500 Hz) Accuracy:
|
|
All other ranges: ± (1.5 % rdg + 4 dgts)
|
| AC Voltage (45 Hz to 500 Hz) Resolution:
|
|
100 μV
|
| AC Voltage (45 Hz to 500 Hz) Input Impedance:
|
|
10 MΩ
|
| DC Current Ranges:
|
|
400 μA, 4 mA, 40 mA, 300 mA, 10 A
|
| DC Current Accuracy:
|
|
400 μA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)
|
| DC Current Accuracy:
|
|
10 A range: ± (2.0 % rdg + 3 dgts)
|
| DC Current Resolution:
|
|
0.1 μA
|
| DC Current Voltage Burden:
|
|
400 μA range: 1 mV/μA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA,
|
| DC Current Voltage Burden:
|
|
300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A
|
| AC Current (45 Hz to 500 Hz) Ranges:
|
|
400 μA, 4 mA, 40 mA, 300 mA, 10 A
|
| AC Current (45 Hz to 500 Hz) Accuracy:
|
|
400 μA to 300 mA ranges: ± (1.5 % rdg + 4 dgts)
|
| AC Current (45 Hz to 500 Hz) Accuracy:
|
|
10 A range: ± (2.5 % rdg + 4 dgts)
|
| AC Current (45 Hz to 500 Hz) Resolution:
|
|
0.1 μA
|
| AC Current (45 Hz to 500 Hz) Voltage Burden:
|
|
See DC Current
|
| Resistance Ranges:
|
|
400 Ω 40 kΩ 4 MΩ
|
| Resistance Accuracy:
|
|
400 Ωand 40 kΩ ranges: ± (1.0 % rdg + 4 dgts)
|
| Resistance Accuracy:
|
|
4 MΩ range: ± (1.2 % rdg + 4 dgts)
|
| Resistance Resolution:
|
|
100 mΩ
|
O P T I O N A L A C C E S S O R I E S
| Part Number
|
|
Description
|
| VC221A
|
|
Padded vinyl, zipper, belt loop
|
| DL248C
|
|
Deluxe test lead kit
|
| DC205B
|
|
no description
|
| HV231-10
|
|
Specialty handheld tester
|
| TP254
|
|
Higher-temperature immersion probe
|
R E P L A C E M E N T P A R T S (supplied with product)
| Part Number
|
|
Description
|
| TL36
|
|
no description
|
| H2-XR
|
|
no description
|
| XR-TA
|
|
no description
|
| TP255
|
|
no description
|
|
Product Reviews
|
|
|